TESTS REQUIRED FOR TANKS AND PIPES WITHIN AND ABOVE GROUND
The method
Tracer Tight ®, certified by the EPA (Environmental Protection Agency) U.S., meets and exceeds the standards set by former ministerial decree 246 of 24/05/1999. Recognized by UNICHIM (M.195 MANUAL Part 2 - 2003 Edition "leak testing of underground tanks") and reported by ARPA Lombardia in the document "Guidelines for Underground Tanks April 2004" among the recognized methods. In addition, the many years of solid experience and the variety of interventions are a valid reference of reliability ', as evidenced by the large number of companies in the world that with full satisfaction using this method for the periodic monitoring of their tanks and pipelines.

 

TRACER TIGHT ® TEST IS CARRIED OUT WITHOUT DISCONTINUE OPERATION 'OF PLANTS
The volumetric
Tracer Tight ® test for the detection of losses is able to locate leaks of less than 0.02 liters / hour from within and above ground tanks and pipelines along several kilometers of the survey is performed without interrupting or interfering in any way affect the operability 'of the plants and requires no' fill it 'emptying the same, also the staff of the station is not involved in the operation. The method allows to examine tanks containing fuels, lubricants, waste water, chemicals and non-volatile, regardless of the size of the tank. This survey method provides for the release, by the potential source of loss, a special volatile chemical "tracer". The tracer is mixed uniformly through the use and dissemination of the product and the loss is spread through the soil, where it evaporates quickly.

 

After initial testing of precision can be made easy and cheap periodical monitoring.
ADVANTAGES OF TRACER TIGHT ®:
 No interruption of service during the test.
 No need 'to fill or empty tanks.
 Can 'run on tanks and pipes of any type or size.
 You can sottopporre control tanks containing all types of products (fuels, lubricants, heating oils,     solvents, sewage, chemicals and non-volatile and volatile hazardous waste), regardless of the type       and size.
 It 'able to locate the source of a leak within a few meters without the need for digging.
 Monotoring later review and cost very interesting.
 It can 'be used for periodic monitoring.
 Establishes and exceeds the standards set by the EPA.

 